dc.description.abstractOne of the most essential data of the social and economic development accepted all around the world is energy. The reasons such as the rapidity of the urbanization and industrialization and rapid increase in population cause to the continuous and indispensable increase in the demand for energy. While the demand for electricity energy is so high, what is important in terms of the user is the submission of the continuous and qualified energy to their own usage. In this study, the failures and power transformer failures occurring in Turkey electricity transmission system have been detected as hourly, monthly and annually and in this way; with the use of these data, the reasons for the failures have been examined and suggestions for solutions have been studied and it has provided opportunities for the conduction of preventive maintenance and repair works in the future. When the failure numbers of 380 kV lines have been examined, it is seen that some lines paint a very negative picture. When the failing lines have been monthly examined, it is seen that there is an accumulation in terms of failure in April-May and August-September periods. By means of this study; the failures occurring in the energy transmission lines have been classified on the basis of hour, month and year and the running reliability of the system in the transmission lines to be established in the future has been determined.tr_TR
dc.language.isoEnglishtr_TR
dc.publisherBitlis Eren Üniversitesitr_TR
dc.rightsinfo:eu-repo/semantics/openAccesstr_TR
dc.subjectTransmission Lines,tr_TR
dc.subjectMaintenance-Repair In The Transmission Lines,tr_TR
dc.subjectShort Circuit Analysis,tr_TR
dc.subjectPower Analysistr_TR
dc.titleThe determination of the running reliability of the system with the method of polynomial regression for electricity transmission linestr_TR
dc.typeArticletr_TR
dc.identifier.issue1tr_TR
dc.identifier.startpage49tr_TR
dc.identifier.endpage52tr_TR
dc.relation.journalBitlis Eren University Journal of Science and Technologytr_TR
dc.identifier.volume6tr_TR


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record