    The determination of the running reliability of the system with the method of polynomial regression for electricity transmission lines

    Thumbnail
    View/Open
    Tam Metin/Full Text (973.4Kb)
    Date
    2016
    Author
    Parlakyıldız, Şakir
    Gençoğlu, Muhsin Tunay
    Metadata
    Show full item record
    Abstract
    One of the most essential data of the social and economic development accepted all around the world is energy. The reasons such as the rapidity of the urbanization and industrialization and rapid increase in population cause to the continuous and indispensable increase in the demand for energy. While the demand for electricity energy is so high, what is important in terms of the user is the submission of the continuous and qualified energy to their own usage. In this study, the failures and power transformer failures occurring in Turkey electricity transmission system have been detected as hourly, monthly and annually and in this way; with the use of these data, the reasons for the failures have been examined and suggestions for solutions have been studied and it has provided opportunities for the conduction of preventive maintenance and repair works in the future. When the failure numbers of 380 kV lines have been examined, it is seen that some lines paint a very negative picture. When the failing lines have been monthly examined, it is seen that there is an accumulation in terms of failure in April-May and August-September periods. By means of this study; the failures occurring in the energy transmission lines have been classified on the basis of hour, month and year and the running reliability of the system in the transmission lines to be established in the future has been determined.
    URI
    http://dspace.beu.edu.tr:8080/xmlui/handle/123456789/13797
    Collections
    • Cilt 06, Sayı 1 (2016) [12]





    Creative Commons License
    DSpace@BEU by Bitlis Eren University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     




    | Yönerge | Rehber | İletişim |

    sherpa/romeo

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsBy Type

    My Account

    LoginRegister

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV