    Development of a Functionalized SiO2 Supported Ni Nanoparticles Based Non-Enzymatic Amperometric Dopamine Sensor

    Thumbnail
    View/Open
    Tam Metin/Full Text (1.776Mb)
    Date
    2024
    Author
    Yunus Emre, YILDIRIM
    Muhammet, GÜLER
    Metadata
    Show full item record
    Abstract
    In the present work, a novel electrochemical dopamine (DA) sensor depending on Nickel (Ni) nanoparticles decorated (3-aminopropyl)triethoxysilane (APTES) modifed silica (SiO2) was fabricated. Hence, Ni@SiO2-APTES was synthesized by the conventional wet-impregnation method. The structure of the compozite was evaluated using Fourier transform infrared spectroscopy (FTIR), Scanning electron microscopy-energy dispersive X-ray (SEM-EDX), and X-ray diffraction (XRD). The synthesized Ni@SiO2-APTES was loaded on glassy carbon working electrode (GCE). Also, Nafion (Nf) was drop-casted on Ni@SiO2-APTES/GCE to stabilize the electrode. The fabricated Nf/Ni@SiO2-APTES/GCE working electrode was electrochemicaly evaluated using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and amperometry. CV and EIS results indicated that Ni nanoparticles increased both the conductivity and sensitivity of the working electrode. The linear detection range for DA was found to be 0.2 – 252 µM with limit of detection (LOD) was 0.07 µM depending on S/N of 3. The sensitivity was found to be 578.26 µA mM-1 cm-2 depending on the active surface area of the modified working electrode. The sensor exhibited excellent selectivity in the electrolyte solution including ascorbic acid, glucose, fructose, sucrose, mannose, uric acid, and phenylalanine. The sensor had satisfactory repeatability and reproduciblity. It was observed that the sensor showed an electrocatalytic response of 95.33% after 28 days. According to this result, it was concluded that the sensor was extremely stable within the studied time period. The applicability of Nf/Ni@SiO2-APTES/GCE was tested using dopamine HCl injection (200 mg/5 mL).
    URI
    http://dspace.beu.edu.tr:8080/xmlui/handle/123456789/15691
    Collections
    • Cilt 13, Sayı 4 (2024) [38]





    Creative Commons License
    DSpace@BEU by Bitlis Eren University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     




    | Yönerge | Rehber | İletişim |

    sherpa/romeo

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsBy Type

    My Account

    LoginRegister

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV