    Thermal Power Plant Performance Analysis by Estimating Boiler Efficiency via Indirect Method: A Case Study

    Thumbnail
    View/Open
    Tam Metin/Full Text (966.2Kb)
    Date
    2024
    Author
    CELEN, Pınar
    ERDEM, Hasan Hüseyin
    Metadata
    Show full item record
    Abstract
    In this paper, a coal (lignite) fired thermal power plant having capacity of 160 MW is taken into consideration and the impact of condenser pressure, moisture content of lignite, excess air coefficient, the efficiency of turbine pressure and heater numbers on power plant thermal efficiency is investigated. It is aimed to determine the performance losses of each equipment by means of thermodynamics and economic analysis. In this scope, it is expected that the power plant operator will be able to evaluate the reduction potential of equipment performance losses and ensure more effective use of the power plants by correctly planning the maintenance and rehabilitation needs and time. In the calculations, the boiler efficiency was determined with EN 12952-15 standard (indirect method) since this method has higher accuracy in coal-fired boilers. It is seen that the condenser pressure and excess air coefficient increments have no significant impact on power plant efficiency compared to moisture content of lignite, excess air coefficient, efficiency of turbine pressure and heater numbers. The significant effect is observed for fuel moisture content which rises from 22% to 47% and the power plant efficiency falls from 40% to 28%. The variation of the power plant thermal efficiency in case of failure of heaters is investigated and the power plant efficiency has decreased from 40.17% to 36.09% when the pre-heaters are no longer in to be in use because of any reason. In addition, revenue losses are estimated for each main equipment efficiency reduction for better use of power plant capacities and electricity lowering production costs.
    URI
    http://dspace.beu.edu.tr:8080/xmlui/handle/123456789/15665
    Collections
    • Cilt 13, Sayı 3 (2024) [32]





    Creative Commons License
    DSpace@BEU by Bitlis Eren University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     




    | Yönerge | Rehber | İletişim |

    sherpa/romeo

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsBy Type

    My Account

    LoginRegister

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV